Sign In | Join Free | My fazendomedia.com
China Guangzhou rongan fire equipment co. LTD logo
Guangzhou rongan fire equipment co. LTD
Guangzhou rongan fire equipment co. LTD
Verified Supplier

2 Years

Home > FM200 Piston Flow System >

Pipeline Type FM200 Piston Flow System Heptafluoropropane Gas Suppression System

Guangzhou rongan fire equipment co. LTD
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Pipeline Type FM200 Piston Flow System Heptafluoropropane Gas Suppression System

  • 1
  • 2

Brand Name : Rongxiao

Model Number : QMQ5.6/150W

Certification : CAL,CMA,CNAS,,CCC

Place of Origin : Guangzhou City, Guangdong Province, China

MOQ : 1 set

Price : Negotiation

Payment Terms : L/C, D/P, Western Union, T/T, Credit card

Supply Ability : 18000 sets per week

Delivery Time : 10 days, subject to quantity negotiation

Packaging Details : Plywood outer box with bubble bag or paper

Agent : FM200 Fire Extinguishing System

Working Temperature : -10°C to 50°C

Type : Piston Flow

Durability : High

Cylinder Capacity : 70L,90L,100L,120L,150L,180L

Cylinder Material : Steel

Driving Device Pressure : 6.0MPa(20℃)

Activation Method : Electric/Pneumatic

Contact Now

Pipeline type FM200 gas suppression system ensures excellent quality

Overview of FM200 Heptafluoropropane Fire Extinguishing System

The external pressure storage type heptafluoropropane fire extinguishing system stores the heptafluoropropane fire extinguishing agent in a liquid state in a container, without nitrogen pressurization. The storage pressure is only the saturated vapor pressure of the fire extinguishing agent, and the compressed gas used as the power for spraying the fire extinguishing agent is stored in another container at a higher pressure. When the system is working, the high-pressure power gas is decompressed by the pressure reducing valve and then injected into the fire extinguishing agent storage bottle (at the same time, the bottle head valve of the container bottle is opened). The power gas pushes the fire extinguishing agent (through the siphon and bottle head valve) to move forward at high speed along the pipe network system, and sprays and extinguishes the fire at the nozzle in the protection area. Since the fire extinguishing agent and the power gas are stored in different containers, two problems can be solved: first, the fire extinguishing agent does not come into contact with nitrogen during storage, and the gas will not be dissolved in the fire extinguishing agent due to the use of nitrogen pressurization; second, after the system is started, the pressure during the transportation and spraying of the fire extinguishing agent is always higher than its storage pressure, and the phenomenon of fire extinguishing agent vapor and nitrogen precipitation will not occur, which effectively alleviates the occurrence of two-phase flow phenomenon during the transportation of the fire extinguishing agent. Therefore, the flow state of the fire extinguishing agent is stable during the transportation process, and the power gas is always at the end of the fire extinguishing agent, pushing the liquid fire extinguishing agent to move rapidly in the pipeline in the form of a single-phase fluid. Its speed is faster and more stable than that of the pressure storage system, which greatly improves the ability of the pipeline to transport the fire extinguishing agent, thereby extending the transportation distance, increasing the spraying pressure of the fire extinguishing agent, and realizing the use of thinner pipelines to transport more fire extinguishing agents. Normally, the pressure in the fire extinguishing agent container is only the saturated vapor pressure of the fire extinguishing agent, and the filling density of the container can be greatly improved; by adjusting the pressure and configuring the amount of nitrogen, the inlet pressure of the fire extinguishing agent nozzle can be increased, which can improve the atomization effect of the fire extinguishing agent and enhance the fire extinguishing effect of the fire extinguishing agent.

Bottle group specifications and storage pressure

Bottle group name Model specification (l) Storage pressure (20℃)
Nitrogen start-up bottle group 8 6Mpa
Nitrogen automatic bottle group 70 13.5Mpa
Fire extinguishing agent bottle group 70 90 120 150 180 0.3Mpa

Company introduction:

Guangzhou Rongan Fire Protection Equipment Co., Ltd. is a professional manufacturer of fire protection facilities integrating R&D, production, design and sales services. The company has experts from the national fire protection industry standards committee and a group of professional technical service teams with more than ten years of experience in the fire protection industry, and will spare no effort to provide you with the most intimate and professional comprehensive technical solutions for fire protection engineering products. "Rongxiao" series products produced by the company have passed the national compulsory product certification and the national fixed fire extinguishing system inspection center, with reliable quality and stable performance, and the factory has passed the ISO9001 quality system certification.

Frequently asked questions:

Q1: Are you a manufacturer or a trading company? A1: We are manufacturers.

Q2: How long is the delivery time? A2:10 days, which can be negotiated according to the quantity.

Q3: How to deal with the fault? A3: During the warranty period, we will provide you with a remote emergency plan during working hours. During the free maintenance period, the company will replace spare parts or complete machines that have failed due to defects or quality problems free of charge.


Product Tags:

Pipeline Type FM200 Piston Flow System

      

Heptafluoropropane FM200 Piston Flow System

      

Heptafluoropropane Gas Suppression System

      
Best Pipeline Type FM200 Piston Flow System Heptafluoropropane Gas Suppression System wholesale

Pipeline Type FM200 Piston Flow System Heptafluoropropane Gas Suppression System Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Guangzhou rongan fire equipment co. LTD
*Subject:
*Message:
Characters Remaining: (0/3000)